Clamp Meters

PROVA 2022AC/DC HVAC TRMS Clamp Meter

PROVA 2022AC/DC HVAC TRMS Clamp Meter

 ․AC/DC current measurement: 40.00A/ 400.0A/ 2000A.

․True RMS measurement of AC current and voltage.

․LoZ (Low input impedance) measurement of AC/DC voltage measurement.

․Auto and full ranges: V, A, Resistance, Continuity, Diode, Capacitance, Micro Current and Temperature.  With AI intelligence, the attributes and ranges of Resistance, Continuity, Diode, Capacitance can be automatically determined.

․Non-contact voltage detection (NCV).

․One Touch Zero for DCA adjustment.

․55mm large jaw diameter.

․Low Pass Filter (LPF) at 1 KHz (-3dB) Cut-off Frequency.

․Fast bar graph display (30 times/sec.) for transient observation.

․Large 3 3/4 digits LCD.

․In-Rush (INR) Current Measurement with 100mS integration time.

․AC/DC voltage accuracy: ±0.5%±2dgts (4/40/400/1000V).

․AC/DC uA current accuracy: ±0.5%±2dgts (400.0uA/4000uA).

․Resistance accuracy: ±0.8%±2dgts (40/ 400/ 4K/ 40K/ 400K/ 4000K/ 40MΩ).

․Capacitance accuracy: ±0.8%±3dgts (4n/ 40n/ 400n/ 4u/ 40u/ 400u/ 4m/ 40mF).

․Temperature measurement: ℃ or ℉.

․Temperature ℃ best accuracy: ±0.5%±0.5℃ (-200.0 ~ 1300℃).

․Temperature ℉ best accuracy: ±0.5%±0.9℉ (-328.0 ~ 2372℉).

․Auto-power-off function (15 minutes).

․Continuity test and Diode Measurement.

․Maximum, minimum and hold functions.

․600V overload protection for ohm / capacitance measurement.

․Backlight.

 

 ․AC/DC current measurement: 40.00A/ 400.0A/ 2000A.

․True RMS measurement of AC current and voltage.

․LoZ (Low input impedance) measurement of AC/DC voltage measurement.

․Auto and full ranges: V, A, Resistance, Continuity, Diode, Capacitance, Micro Current and Temperature.  With AI intelligence, the attributes and ranges of Resistance, Continuity, Diode, Capacitance can be automatically determined.

․Non-contact voltage detection (NCV).

․One Touch Zero for DCA adjustment.

․55mm large jaw diameter.

․Low Pass Filter (LPF) at 1 KHz (-3dB) Cut-off Frequency.

․Fast bar graph display (30 times/sec.) for transient observation.

․Large 3 3/4 digits LCD.

․In-Rush (INR) Current Measurement with 100mS integration time.

․AC/DC voltage accuracy: ±0.5%±2dgts (4/40/400/1000V).

․AC/DC uA current accuracy: ±0.5%±2dgts (400.0uA/4000uA).

․Resistance accuracy: ±0.8%±2dgts (40/ 400/ 4K/ 40K/ 400K/ 4000K/ 40MΩ).

․Capacitance accuracy: ±0.8%±3dgts (4n/ 40n/ 400n/ 4u/ 40u/ 400u/ 4m/ 40mF).

․Temperature measurement: ℃ or ℉.

․Temperature ℃ best accuracy: ±0.5%±0.5℃ (-200.0 ~ 1300℃).

․Temperature ℉ best accuracy: ±0.5%±0.9℉ (-328.0 ~ 2372℉).

․Auto-power-off function (15 minutes).

․Continuity test and Diode Measurement.

․Maximum, minimum and hold functions.

․600V overload protection for ohm / capacitance measurement.

․Backlight.